Site Classification

Site Classification – 2.1.2 – Site Classification based on soil reactivity

All sites are required to be classified. The footing system by the engineer has to be suitable for each and individual site and the only method of achieving this is to assess the site and it to classify it.

The main soil types are sand and clay, with silt as an intermediate type.

The various types of soil are distinguished in an engineering assessment by the size of the particles that constitute the soil such as follows;

  • sand – which comprises material down to 0.075 mm;
  • silt – which includes the range 0.075 mm to 0.002 mm; and
  • clay – which consists of very fine particles smaller than 0.002 mm.

Continue reading “Site Classification”

Strip Flooring

Strip Flooring 5.4.1

Fitted flooring shall be kept 10 mm clear of walls or wall plates that are parallel to the length of the boards of strip flooring.

The end-matched flooring may be laid with end joints between joists, provided end joints are joined tightly together and well distributed and end-matched joints in adjoining boards do not fall within the same joist spacing.

Strip flooring board lengths shall be at least the equivalent of two joist spacing’s to ensure strength in the overall floor. Finger-jointed hardwood flooring that is manufactured in accordance with AS 2796.1 shall be considered equivalent to continuous strip flooring.

Continue reading “Strip Flooring”

Wall Framing

Wall Framing – General 6.1

Application – This section sets out requirements for the construction of conventional stud-framed walls and shall be used in conjunction with Span Tables of the Timber Framing Code.

Bracing – Temporary and permanent bracing shall be provided to stud walls to resist horizontal forces applied to the building. Appropriate connections shall also be provided to transfer these forces through the framework and sub-floor structures to the building foundation.

Continue reading “Wall Framing”